Coop & Run Lighting Planner
A light plan for your flock.
Draw your hen house and run. Tell us where breakfast happens. Find a starting light-line layout and the kits to bring it to life.
Coverage estimate—not a measured lighting or electrical design. Walls, mounting height and cable routing matter.Your location, sunlight & flock
See local daylight through the year, find a better sensor location, and explore when supplemental morning lighting may support your hens.
This is planning guidance, not a prediction of eggs or a programmed SOLAYE schedule. SunSync responds to the daylight measured at the sensor.
Choose a nearby city for a regional estimate, or enter your own coordinates and time zone. City-center coordinates are approximate. No address or device location is collected. Times include daylight-saving changes where applicable.
Tree cover & sensor placement
Optional winter-shadow check
Enter feet for this check. It approximates the shadow from one obstacle at solar noon on the winter solstice, on level ground. It does not model tree transparency, hills, morning/evening shade or every branch.
Your hens
Add each hen’s breed and age in months today. Ages advance in the monthly outlook.
Breed categories describe general laying background; they do not establish a measured response to this product. Hatchery strain, health, nutrition, temperature, molt and broodiness can outweigh light effects.
Pause and laying-status settings are saved separately for each hen during this visit. Enter known pauses; the planner does not invent a molt calendar.
| Month | Sunrise / sunset | Daylight | Hen age | Lighting outlook |
|---|
Monthly times represent the 15th, not a monthly average. “Below 14 hours” is a daylight screening reference drawn from extension guidance, not a validated threshold for every hen or an instruction to set the controller. Outdoor shade affects intensity and sensor readings; we do not subtract invented hours of daylight. Lighting cannot reverse aging or guarantee laying through molt or broodiness. For immature pullets, use age-appropriate rearing guidance rather than stimulating early laying.
Sources & assumptions
Sunrise and sunset use NOAA’s approximate fractional-year solar equations, with a 90.833° sunrise/sunset zenith and a clear, level horizon. Clouds, terrain, foliage and sensor thresholds can make actual detection different. High-latitude results need local review. Sensor guidance is a site-screening inference from the sun path, not a measured light survey; follow the instructions supplied with your model.
- NOAA solar equations
- University of Minnesota: age, breed and seasonal laying
- Utah State: maturity, light and molt
- SOLAYE installation and model guidance
No numerical egg-uplift model is applied. The outlook flags daylight limitation and life stage independently. This section does not increase your recommended light-line count: runs used only at or after sunrise remain excluded.
Your spaces
Hen house
Breakfast spots
Drag the food and water markers, or select a marker below the plan and use its position sliders.
Drag a space to move it. Drag its gold corner to resize. Drag food and water between spaces; move lights within their room. Dimensions and recommendations update as you resize.
Lighting recommendation
Each separate room or run receives its own controller kit in this estimate. This avoids assuming cables can cross walls or span between buildings. A verified layout may allow consolidation.
How this recommendation works
We divide each lit space by 150 sq. ft. and round up, with at least one light per separate room. A run needs supplemental lighting only when hens can enter it before sunrise. If run access begins at sunrise or later, only the hen house is included. The house remains included even when food and water are in the run.
Each 0.5-meter light line is rated for up to 150 sq. ft. of unobstructed space. This is an area-based estimate, not a lux map. Suggested positions favor food and water in accessible areas, then distribute remaining lights across the space. The diagram does not simulate brightness, shadows or mounting height.
Each controller supports five light lines. Layouts needing more than five in one space, or unusually long narrow spaces, are referred for review rather than automatically sold a configuration. Keep the sensor exposed to natural daylight per the supplied instructions; keep food and water away from electrical connections.